Introducing the SHR2DN Intelligent Motor Soft Starter, a cutting-edge solution crafted by leading China suppliers in industrial automation. This advanced device is engineered with the latest digital processing technology, enabling efficient voltage adjustment and electric current limitation. The SHR2DN features an innovative electronic circuit that ensures optimal control and protection, allowing for linear acceleration at higher speeds. It offers programmable start-stop controls, making it ideal for low-speed pump operations and rapid reversals in electro-controlled systems, With customizable dual start-stop parameters, the SHR2DN can monitor load conditions and automatically switch between energy-saving and light load modes. Its robust protective functions include electrical insulation testing and safeguards against short circuits and phase losses. Plus, the built-in RS485 communication interface supports Modbus/Profibus protocols for seamless long-range control and monitoring, This versatile soft starter is extensively used across various industries, including textile, metallurgy, petrochemical, water treatment, shipping, pharmaceuticals, food processing, mining, and mechanical equipment manufacturing. Trust the SHR2DN from a reliable China factory to enhance your operational efficiency and ensure the longevity of your machinery

    Product Profile

    SHR2DN is a new intelligent motor soft starter,SHR2DN withthe most advanced digital processor which can adjust voltageand limit the electric current. The unique intelligent electronic circuit offers perfect control andprotective function: Start linearly with higher speed, starting and stopping control of the pumppreset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realizeautomatically run with energy-saving or light load mode. The protective function of electricalmachinery insulating testing , and the protection of short circuit, phase loss and the electronicRS485 with communication interface use modbus/profibus protocol that generally realize the long.range control and monitoring. Can be extensively used in textile industry, metallurgy industrypetrochemical industry, water treatment, shipping industry, medicine, food processing industrymine industry and mechanical equipment industry etc.

    Function

    • Multinational language supported, LcD display, set up the parameter in button type
    • RS485 with communication interface modbus/profibus protocol
    • Can programme set the signal relay
    • Super strong perfect control and protective function
    • Can be run online continuously without bypass. High reliability
    Soft starter 202003 PriVersion3(1)-42.jpg

    Parameters

    230-690V Motor Power
    Motor Power (KW) Size and Type of softstarter
    230V 400V 500V 690V Bypass Main voltage Control voltage Control inputs Functions Options
    4 7.5 11 15 SHR2DN17 -x -x -x -× + X…
    7.5 15 18.5 25 SHR2DN31 -x -x -x -× + ×…
    15 22 25 37 SHR2DN44 -x -x -x -x + x…
    18.5 30 37 55 SHR2DN58 -x -x -x -× + ×…
    22 37 45 59 SHR2DN72 -x -x -x -x + x…
    25 45 55 75 SHR2DN85 -x -x -x -× + ×…
    30 55 75 90 SHR2DN105 -x -x -x -× + ×…
    37 75 90 132 SHR2DN145 -x -x -x -x + x…
    45 90 110 160 SHR2DN170 -x -x -x -× + ×…
    55 110 132 200 SHR2DN210 -x -x -x -×+ ×…
    75 132 160 220 SHR2DN250 -x -x -x -X + X…
    90 160 200 257 SHR2DN310 -x -x -x -× + ×…
    110 200 250 355 SHR2DN390 -x -x -x -X + X…
    132 250 315 450 SHR2DN460 -x -x -x -× + ×…
    160 315 400 560 SHR2DN580 -x -x -x -×+×…
    200 400 500 710 SHR2DN720 -x -x -x -× + ×…
    250 450 560 800 SHR2DN820 -x -x -x -x + x…
    280 500 630 850 SHR2DN950 -x -x -x -X + X…
    Purchasing guide
    For normal duty applications, we recommend the same rated power HPS2DN softstarters. As pump compress or elevator, escalator conveyor belt(short)
    For heavy duty applications, we recommend one higher level HPS2DN soft starters.As centrifugal, fan,mill,mixer conveyor belt(long)

    Parameters

    General information
    Supply voltage Line to line 230V-690V (to be specified) 10%
    Frequency 50/60Hz 4Hz(dual frequency)
    Control Supply 110-120V of 220-240V (to be specified)
    Control Inputs and Outputs 110-120V of 220-240V (to be specified)
    Load 3 phase, 3 wire, squirrel cage induction motor
    Operating temperature 0℃ to 50℃
    Storage temperature -20 ℃t o 70℃
    Maximum starting time 30 seconds
    Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications
    Operating parameters
    Starter FLC Starter Full Load Current 17~950 Amp
    Motor FLA Motor Full Load Ampere 50%-100% of starter FLC
    Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop
    Pulse start duration A pu lse of 80% Un for adjustable time 0-1 second, to start high friction loads
    Initial voltage 10%-50% Un*(can be extended to 80% Un)
    Current limit 100%-400% of Motor FLA* (can be extended to 500%)
    Ramp-up time 1-30 seconds (can be extended to 90s*)
    Ramp-down time 1-30 seconds(can be extended to 90s*)
    Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA.
    Energy saving Activated when motor is lightly loaded for extended periods of time
    Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds
    Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tach o feedback linearity
    Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8, for dual adjustment)
    Motor protection
    Too many starts Determines maximum number of starts allowable during Start Period Rangel-10starts in start period 1-60minutes
    Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated
    Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds*
    Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running
    Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds
    Under current Starter trips when current drops below 20%-90% In, time del ay 1-40 seconds
    Under voltage(**) Starter trips when mains voltage drops below 120–600V, time del ay 1–10 seconds
    Over voltage Starter trips when mains voltage increases above 150-750Vtime del ay 1-10 seconds
    Phase loss,(under/ over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency
    Phase sequence Starter trips when phase sequence is incorrect
    Long slow speed time Starter trips if operating at slow speed longer than 30 seconds
    Wrong connection Prevents starting if the motor is incorrectly connected to the starter
    Shorted SCR Prevents starting when one or more SCRs are shorted
    Heatsink over temperature Starter trips when heatsink temperature rises above 85
    External fault Starter trips when an external contact closes for 2 seconds
    Motor insulation(optional) Alarm level setting 0.2-5M. Trips when motor insulation decreases below 0.2-5M setting. The thyristors must be protected against short circuit
    Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits
    Control
    Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current
    Displays LCD in 4 selectable languages and 8 LEDs
    Keypad 6 clearly defined keys for easy setting
    Aux. contact-immediate 1 C/O,8A,250V A. C,2000VA(delay 0-60 seconds)
    Aux. contact-end of acceleration 1 C/O,8A,250V A. C,2000VA(del ay 0-120 seconds)
    Fault contact 1 C/O,8A,250V A. C,2000VA(selectable as trip or trip fail safe)
    Insulation alarm contact(optional) 1 C/O,8A,250V A. C,2000VA
    Communication(optional) RS 485 with Modbus/ Profibus protocol for full control and supervision

    Measurement

    Soft starter 202003 PriVersion3(1)-47.jpg

    Frequently Asked Questions

    What is the primary function of the SHR2DN soft starter?
    The SHR2DN is an intelligent motor soft starter designed with an advanced digital processor to adjust voltage and limit electric current. It provides linear start control, adjustable starting/stopping parameters, and comprehensive protective functions for industrial machinery.
    What communication protocols are supported by the SHR2DN?
    The soft starter features an RS485 communication interface that supports Modbus and Profibus protocols, allowing for seamless integration into long-range control and monitoring systems.
    How do I choose the correct soft starter for heavy-duty vs. normal-duty applications?
    For normal duty applications (such as pumps, compressors, escalators, and short conveyor belts), select the soft starter with the matching rated power. For heavy-duty applications (such as centrifugal fans, mills, mixers, and long conveyor belts), we recommend choosing a soft starter that is one level higher.
    Can the SHR2DN soft starter run continuously without an external bypass?
    Yes, the SHR2DN soft starter is engineered to run online continuously without the need for a bypass, offering high system reliability and simplified installation.
    What built-in motor protection mechanisms does it feature?
    The device features robust motor protection, including protection against too many starts, start inhibit, long start times (stall protection), electronic fuses (shear pin), electronic overload, under/over current, under/over voltage, phase loss, wrong connection, and heatsink over-temperature.