China SHSS600 Photovoltaic Water Pump Inverter - Factory Suppliers with MPPT Technology for Maximum Solar Power Output
Product Overview
The SHSS600 photovoltaic water pump inverter utilizes MPPT (Maximum Power Point Tracking) technology and advanced motor drive techniques to maximize the power output from solar panels. The SHSS600 supports both DC and AC input, and its AC output is compatible with a wide range of standard AC water pumps. When sunlight is unavailable or too weak to power the pump, the inverter automatically switches to single-phase or three-phase AC input—such as from a generator or the utility grid.
The SHSS600 offers comprehensive protection features—including dry-run prevention, low-solar detection, full-tank detection, and automatic fault diagnostics—as well as soft start and speed control functions for the motor. It is feature-rich, user-friendly, and easy to install.
Additionally, the SHBF600 provides a remote monitoring solution, enabling users to remotely access real-time operational data and fault information.
System Structure & Working Principle
It consists of a solar panel array, a photovoltaic water pump inverter, an AC water pump, and a storage tank, using solar energy as its power source to draw water from sources such as deep wells, rivers, or lakes via the pump.
Working Principle
The solar panel array absorbs sunlight and converts it into electrical energy to power the system. The photovoltaic water pump inverter converts the direct current (DC) output from the solar array into alternating current (AC) to drive the water pump. It continuously adjusts voltage and frequency in real time according to solar irradiance, implementing Maximum Power Point Tracking (MPPT) to maximize solar energy utilization. When sunlight is insufficient, the system can switch to grid power as a supplementary source.
System Features
- Automatic start/stop (starts at sunrise, stops at sunset); no backup batteries required - operates whenever there is sunlight.
- Adaptable to various water-demand scenarios; compatible with all types of solar panels and AC water pumps (e.g., self-priming pumps, submersible pumps).
- Operates reliably in ambient temperatures up to 60°C.
- Supports GPRS remote monitoring of operational status and remote start/stop control.
- Stable performance even on cloudy days; higher long-term ROI compared to diesel generators.
- Built-in comprehensive protection functions; fully automatic operation requires no dedicated personnel.
Application Scenarios
Primarily used for daily water supply, agricultural and forestry irrigation, desertification control, livestock watering, wastewater treatment, landscape fountains, swimming pools, and similar applications.
Key Highlights & Features
Flexible
- Suitable for various pumps, including single-phase 220V pumps
- Compatible with all specifications of photovoltaic modules
- Supports AC/DC input, can switch to mains power, 24-hour operation
Smart
- Built-in maximum power point tracking technology, efficiency up to 99%
- Self-adaptive motor power
- Built-in water level monitoring function, automatically adjusts water volume, prevents dry running, overfilling, etc.
High Cost-Performance
- Wide voltage input range
- Plug-and-play system design, no parameter settings required
- No battery required, suitable for various application scenarios
- Easy installation and maintenance
Reliable
- Leading motor & pump drive technology with over 10 years of market application experience
- Soft start function prevents water hammer effect, extends system life
- Built-in comprehensive protection against overvoltage, overload, undervoltage, weak light, etc.
Remote Monitoring
- Optional GPRS module for remote monitoring system
- Supports remote monitoring via PC web interface
- Monitor solar water pump systems anytime, anywhere & view historical parameters
- Standard RS-485 interface, can be remotely monitored via MaiKaiNuo SCADA software on a PC
Technical Specifications
| Technical Specifications | Description | |
|---|---|---|
| 220V Inverter | 380V Inverter | |
| Input DC Voltage Range | 200‑400V | 300‑800V |
| Maximum Input DC Voltage | 400V | 800V |
| Recommended MPPT Voltage Range | 280‑350V | 480‑600V |
| MPPT Efficiency | 99.9% | |
| Input AC Voltage Range | Single/Three‑phase 220/230/240V | Three‑phase 380/415/440V |
| Output AC Voltage Range | Single/Three‑phase 0~220/230/240V | Three‑phase 0~380/415/440V |
| Output Frequency Range | 0~320Hz | |
| Protection Class | IP20 | |
| Fault Protection Function | Provides over 30 common fault protection functions, including overcurrent, overvoltage, undervoltage, overheating, phase loss, overload, and short circuit; special protection features include water‑level sensor failure detection, full‑tank and dry‑run prevention, and low‑solar irradiance warnings. The inverter records detailed operational status at the time of a fault and features an automatic fault reset function. | |
Product Selection
| Model | Motor | Rated Output Current (A) | Suggested Open‑Circuit Voltage (V) | |
|---|---|---|---|---|
| Power (kW) | Horsepower (HP) | |||
| Three‑phase 220V | ||||
| SHSS600‑02T0.75G | 0.75 | 1 | 4 | 350~440V |
| SHSS600‑02T1.5G | 1.5 | 2 | 7 | |
| SHSS600‑02T2.2G | 2.2 | 3 | 9.6 | |
| SHSS600‑02T4G/5.5P | 4 | 5 | 17 | |
| SHSS600‑02T5.5G/7.5P | 5.5 | 7.5 | 25 | |
| SHSS600‑02T7.5G/11P | 7.5 | 10 | 32 | |
| SHSS600‑02T11G/15P | 11 | 15 | 45 | |
| SHSS600‑02T15G/18.5P | 15 | 20 | 60 | |
| SHSS600‑02T18.5G/22P | 18.5 | 25 | 75 | 350~440V |
| Three‑phase 380V | ||||
| SHSS600‑04T0.75G | 0.75 | 1 | 2.1 | 625‑750V |
| SHSS600‑04T1.5G | 1.5 | 2 | 3.8 | |
| SHSS600‑04T2.2G | 2.2 | 3 | 5.1 | |
| SHSS600‑04T4G/5.5P | 4 | 5 | 9 | |
| SHSS600‑04T5.5G/7.5P | 5.5 | 7.5 | 13 | |
| SHSS600‑04T7.5G/11P | 7.5 | 10 | 17 | |
| SHSS600‑04T11G/15P | 11 | 15 | 25 | |
| SHSS600‑04T15G/18.5P | 15 | 20 | 32 | |
| SHSS600‑04T18.5G/22P | 18.5 | 25 | 37 | |
| SHSS600‑04T22G/30P | 22 | 30 | 45 | |
| SHSS600‑04T30G/37P | 30 | 40 | 60 | |
| SHSS600‑04T37G/45P | 37 | 50 | 75 | |
| SHSS600‑04T45G/55P | 45 | 60 | 91 | |
| SHSS600‑04T55G/75P | 55 | 75 | 110 | |
| SHSS600‑04T75G/90P | 75 | 100 | 150 | 625‑750V |
| SHSS600‑04T90G/110P | 90 | 125 | 176 | |
| SHSS600‑04T110G/132P | 110 | 150 | 210 | |
1. Depending on the lighting conditions in different regions, the power of the photovoltaic array should be at least 1.3 times that of the pump.
2. When using a deep well pump or in situations where the inverter output power line is long, the inverter needs to be derated and an output reactor must be installed.
Wiring Diagram
Frequently Asked Questions (FAQ)
No, the SHSS600 is designed as a direct-drive battery-free system. It operates automatically whenever sunlight is available, starting at sunrise and stopping at sunset, significantly reducing system investment and maintenance costs.
Yes. The inverter supports dual AC/DC input. When solar radiation is insufficient or absent, it can automatically switch to single-phase or three-phase utility grid power or a diesel generator for uninterrupted 24-hour operation.
It is compatible with standard AC water pumps, including single-phase 220V pumps and three-phase 220V/380V pumps, such as deep-well submersible pumps, surface self-priming pumps, and centrifugal pumps.
The inverter features built-in smart water level detection and dry-run protection. It automatically stops the motor when water in the well is low or when the storage tank is full, and resets automatically when normal levels return.
Depending on regional light conditions, the total solar panel array power is recommended to be at least 1.3 times the rated power of the water pump to ensure optimal operation even on partially cloudy days.
Users can utilize the optional GPRS module to access live and historical data via a PC web interface, or connect via standard RS-485 to MaiKaiNuo SCADA software for centralized PC monitoring and start/stop control.