High-Quality Solid-State Soft Starter Cabinets for Medium and High Voltage Motors from China Suppliers and Factory
Application Industry
Features
-
A digital microprocessor is used to manage data and communication. Signal grading processing and isolation technology are adopted, enabling the system to have strong anti-interference ability. Moreover, the equipment control is real-time and efficient, with good stability and high reliability.
-
Advanced optical fiber transmission control technology is used to trigger high-voltage thyristors.
-
Safe isolation between the detection and high-low voltage control circuits ensures high safety.
-
High-frequency power supply isolation and transformation technology are used to provide a safe and reliable working power supply for electronic devices operating in the high-voltage part.
-
The static and dynamic voltage equalization and absorption technology of the resistance-capacitance network ensures the reliable and safe operation of power devices in series under high voltage.
-
The electronic EVT (Electronic Voltage Transformer) technology is adopted. Electronic sampling and optical fiber transmission are free from interference and phase shift.
-
Starting curves are designed to adapt to the mechanical characteristics and requirements of different motor systems. The motor torque is automatically adjusted to obtain a smooth acceleration curve and reduce electrical and mechanical shocks during the starting process.
-
Stopping curves are provided to adapt to the mechanical characteristics of different loads. There is a function of adjustable final torque, which effectively prevents the water hammer effect caused by the shutdown of pump-type loads.
-
The pulse jump function improves the initial starting torque and is suitable for high-static-resistance torque systems.
-
Protection functions: Over-voltage, under-voltage, multiple overload protection curves, under-current, phase loss, phase imbalance, wrong phase sequence, zero-sequence grounding protection, thyristor over-temperature, excessive starting time, starting interval limitation, thyristor failure protection, etc.
-
The V-DN series high-voltage solid-state soft starters can use a low-voltage (380V) motor for simulation debugging before on-site high-voltage operation, providing technical data and guarantees for formal operation.
-
The cabinet adopts the KYN28A-12 structure type. The materials are imported aluminum-zinc-coated steel plates, which have the advantages of corrosion resistance, oxidation resistance, novel and beautiful appearance, and high protection level. It can also be conveniently combined with the KYN28A-12 standard middle-installed cabinet.
-
The speed feedback control function: For occasions requiring linear acceleration and deceleration, a speed feedback unit can be optionally connected to obtain the linear acceleration and deceleration characteristics of the motor. (Optional)
-
For the occasion of generator-powered motors, a special control program is set to ensure successful starting under unstable voltage, current, and frequency conditions. With appropriate reactive power compensation, a lightly-loaded motor can be successfully started when the generator capacity is more than 1.35 times the apparent power of the motor.
-
Parameter adjustment function: For two-speed motors, or in the case of power supply from the power grid/generator, or when the parameters of two motors are different in a one-drag-two situation.
-
Two sets of starting and stopping parameters can be input. The required set of parameters can be conveniently selected through programmable terminals for starting and operation.
-
It has a friendly human-machine operation interface and historical data statistical query function. If necessary, a touch-screen interface can be optionally selected to better realize human-machine information exchange.
-
It has an RS485 interface, and communication protocols (Modbus/Profibus) are optional, which is convenient for users to achieve centralized monitoring.
-
Insulation detection function. (Optional)
Performance Parameters
-
Control mode: Pulse jump starting, voltage ramp, constant current, speed control (optional)
-
Starting method: Soft start, direct start, soft stop, free stop.
-
Operation mode: Control on the cabinet, external control, communication remote control (optional)
-
Communication method: RS485 interface; Modbus protocol and Profibus protocol (optional)
-
Analog output: Motor operating current, with the signal being 0-10V or 4-20mA or 0-20mA.
-
Initial voltage: 10%~50% Un (can be extended to 5%~80% Un)
-
Current limiting multiple: 100%~400% In (can be extended to 500% In)
-
Starting and stopping time: 1~30S (can be extended to 90S)
-
Starting pulse jump: Current, 70%-700% In (when the pulse jump time is 0~10 seconds)
-
Parameter setting: 1--Control panel buttons; 2--Background communication setting.
-
Liquid crystal display: Parameters such as working current, number of starts, running time, and fault information, etc. Default languages: Chinese(English), German, French, Spanish.
-
Noise level: <80dB
-
Continuous starting interval: When the ambient temperature is higher than 40°C and the starting current is greater than 400% In, the interval should not be less than 30 minutes. When the temperature is relatively low and the starting current is relatively small, the interval can be appropriately reduced, but it should be at least 15 minutes.
-
Cooling method: Natural cooling.
-
Operation power supply: AC220V/50Hz600VA (Special requirements need to be specified separately)
-
Power frequency withstand voltage of the main circuit: 42KV/1minute (excluding the power unit)
-
Protection mode: Composite (See the introduction of protection functions)
-
Protection level: IP42 (IP54 can be selected for special requirements)
Working Environment
Temperature Limits
Operating Temperature: -10℃ to 50°C
Storage Temperature: -20℃ to 70℃ (Special conditions should be declared when placing an order)
Humidity & Atmosphere
Relative humidity should not exceed 95% at +50°C. Higher relative humidity is allowed at lower temperatures.
No explosion-hazard and corrosive gases. Pollution degree: ≤3 (can be increased to 4).
Vibration & Altitude
Vibration: Frequency 10 Hz to 150 Hz, acceleration not more than 0.5m/s².
Altitude: ≤1000 m (can be extended to 4000 m).
Main Circuit Power Supply
Three-phase, 10kV/50 Hz. Continuous voltage fluctuation should not exceed -15% to +10%.
Frequency fluctuation should not exceed ±5 Hz, change rate not exceeding ±1% per second.
Components of the soft starter
The high-voltage devices in the high-voltage compartment mainly include high-voltage thyristor components, EVT-TX (voltage signal transmitter), current transformers, trigger boards, bypass switches, etc.
The low-voltage devices in the low-voltage compartment mainly include the main control circuit, EVT-RX (voltage signal receiver), signal converters, setting units, input and output units, power supplies, etc.
Model Selection
The products with a voltage level of 3.3kv can be used to replace those with a voltage level of 2.3kv; the products with a voltage level of 6.0kv can be used to replace those with a voltage level of 4.16KV and 6.6KV.
The soft starter must be selected according to the rated current indicated on the motor nameplate even if the motor is not operating at full load. The corresponding kW values given in the table are for reference only. However, it should be noted that when the motor powers at different voltage levels are the same, the currents are different. When selecting the model, please calculate the current according to the power and then confirm.
| Model | Voltage (KV) | Current (A) | Power (kW) | Size W*D*H (mm) |
|---|---|---|---|---|
| SHMV-DN-03-60 | 3 | 60 | 265 | 1000*1300 (1500) *2300 |
| SHMV-DN-03-100 | 3 | 100 | 442 | 1000*1300 (1500) *2300 |
| SHMV-DN-03-200 | 3 | 200 | 883 | 1000*1300 (1500) *2300 |
| SHMV-DN-03-300 | 3 | 300 | 1325 | 1000*1300 (1500) *2300 |
| SHMV-DN-03-400 | 3 | 400 | 1767 | 1000*1300 (1500) *2300 |
| SHMV-DN-03-600 | 3 | 600 | 2650 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-03-800 | 3 | 800 | 3533 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-03-1000 | 3 | 1000 | 4417 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-03-1200 | 3 | 1200 | 5300 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-03-1400 | 3 | 1400 | 6183 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-06-60 | 6 | 60 | 530 | 1000*1300 (1500)*2300 |
| SHMV-DN-06-100 | 6 | 100 | 883 | 1000*1300 (1500)*2300 |
| SHMV-DN-06-200 | 6 | 200 | 1767 | 1000*1300 (1500) *2300 |
| SHMV-DN-06-300 | 6 | 300 | 2650 | 1000*1300 (1500) *2300 |
| SHMV-DN-06-400 | 6 | 400 | 3533 | 1200*1300 (1500)*2300 |
| SHMV-DN-06-600 | 6 | 600 | 5300 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-06-800 | 6 | 800 | 7067 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-06-1000 | 6 | 1000 | 8833 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-06-1200 | 6 | 1200 | 10600 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-06-1400 | 6 | 1400 | 12366 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-10-60 | 10 | 60 | 883 | 1000*1300(1500)*2300 |
| SHMV-DN-10-100 | 10 | 100 | 1472 | 1000*1300 (1500)*2300 |
| SHMV-DN-10-200 | 10 | 200 | 2944 | 1000*1300 (1500) *2300 |
| SHMV-DN-10-300 | 10 | 300 | 4417 | 1200*1300 (1500) *2300 |
| SHMV-DN-10-400 | 10 | 400 | 5889 | 1200*1300 (1500)*2300 |
| SHMV-DN-10-600 | 10 | 600 | 8833 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-10-800 | 10 | 800 | 11778 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-10-1000 | 10 | 1000 | 14722 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-10-1200 | 10 | 1200 | 17666 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-10-1400 | 10 | 1400 | 20611 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-60 | 13.8 | 60 | 1219 | 1000*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-100 | 13.8 | 100 | 2032 | 1000*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-200 | 13.8 | 200 | 4063 | 1000*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-300 | 13.8 | 300 | 6095 | 1000*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-400 | 13.8 | 400 | 8127 | 1000*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-600 | 13.8 | 600 | 12190 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-800 | 13.8 | 800 | 16253 | 2500*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-1000 | 13.8 | 1000 | 20316 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-1200 | 13.8 | 1200 | 24380 | 3250*1660*2400 (Subject to actual situation) |
| SHMV-DN-13.8-1400 | 13.8 | 1400 | 28443 | 3250*1660*2400 (Subject to actual situation) |
Ordering Information
Instructions Related to the Cabinet:
The main method of cable inlet and outlet for this product is bottom-in and bottom-out. Therefore, there should be a cable channel of sufficient size under the foundation. Protective plates can be added to both sides of the cabinet as required, with each side plate being 25mm thick. (Please specify when placing an order if needed. This product undergoes a powder coating treatment on its surface. The default color is Computer Grey: MB2071 (RAL7032). Please specify when placing an order if there are special color requirements.)
By default, the opening direction of the front door of the low-voltage compartment is to the right.
If there are other special requirements regarding the cabinet's form, dimensions, etc., we can customize, design, and manufacture it according to the user's requests.
Ordering Information and Examples:
Select the starter according to the rated current of the motor and the working mode, and write down the complete product specification and model as specified by the product model.
When there are differences from the standard configuration in the sample, please clearly state them separately in the contract (or technical agreement).
When placing an order, customers are required to provide the specification and model of the equipped motor, the main parameters, as well as the type and characteristics of the driven equipment.
Frequently Asked Questions (FAQ)
Can the V-DN series soft starter be debugged before high-voltage operation?
Yes. The V-DN series high-voltage solid-state soft starters support simulation debugging using a low-voltage (380V) motor prior to on-site high-voltage operation. This provides critical technical data and guarantees for a safe formal operation.
What are the standard cabinet features and options?
The cabinet uses a KYN28A-12 structure made of imported aluminum-zinc-coated steel plates. It features bottom-in and bottom-out cable entry, a right-opening door for the low-voltage compartment, and a standard Computer Grey (RAL7032) powder-coated finish. Optional 25mm thick side protective plates and custom dimensions or colors are available upon request.
How do I select the correct model for my motor?
You must select the soft starter based on the rated current indicated on your motor nameplate, even if the motor does not run at full load. Do not rely solely on the kW reference values, as currents differ at varying voltage levels even if the kW rating is the same.
What are the environmental requirements for installation?
The equipment operates in temperatures from -10°C to 50°C with relative humidity up to 95% (at 50°C). It requires a non-explosive, non-corrosive atmosphere (pollution degree ≤3, extendable to 4), vibration acceleration below 0.5m/s², and altitudes ≤1000m (extendable up to 4000m).
What protection functions are integrated into the starter?
The system features comprehensive protection including over-voltage, under-voltage, multiple overload protection curves, under-current, phase loss, phase imbalance, wrong phase sequence, zero-sequence grounding protection, thyristor over-temperature, excessive starting time, starting interval limitation, and thyristor failure protection.
What information is required when placing an order?
Customers must provide the specific model of the soft starter based on the motor's rated current, the specifications and main parameters of the equipped motor, and the type/characteristics of the driven equipment. Any deviations from the standard configuration should be declared in the contract or technical agreement.