SHBF700 Enhanced General Purpose Inverter from China Suppliers - High-Performance Motor Control Factory Device
Application Industry
Standard Configuration
-
1
“Dual digital display” keyboard
-
2
485 communication, support Ethernet extension cable
-
3
5 digital input terminals, support 100KHz pulse signal, support input signal polarity selection
-
4
One relay output
-
5
Support one 100KHz pulse signal output, support parameter setting "two relays", multi-functional expansion interface supports "eight relays"
-
6
3 channels of analog input, AI1 and AI2 are independent, both support current 0/4-20mA or voltage 0~10V input, AI3 fixed panel potentiometer
-
7
One channel of voltage and current analog output
-
8
Provide +10V and +24V two-way power supply at the same time
-
9
Brake unit
-
10
Simple PLC, support PID modification setting
-
11
Sixteen-stage speed control
-
12
4 groups of acceleration and deceleration time settings
-
13
VF mode, support fire emergency EPS
-
14
Jump frequency mode, frequency detection
-
15
High frequency output, support 3000Hz
-
16
Run/ stop timing
-
17
Use time timing, support random password release, avoid malicious arrears
-
18
External temperature detection, support constant temperature control
-
19
The whole series of models will not explode in short circuit, input and output phase loss protection + conventional function protection
-
20
Support switching of parameter positions between main display and auxiliary display, and support arbitrary selection of display target content
-
21
One drag four constant pressure + auxiliary pump function, support arbitrary selection mode
-
22
Integrated one drag four constant + auxiliary pump operation status display
-
23
Support low-power single-phase 220V boost three-phase 380V
-
24
Support modification or addition of functional items, focus on meeting specific users and partners, customize differentiated special products, and facilitate coverage of wider market needs.
Running Control
Linear V/F control, square V/f control, V/F separation mode, SVPWM modulation
G model: 150% overload for 60s, 180% overload for 3s
P model: 120% overload for 60s, 150% overload for 3s
1.0KHz ~ 8.0KHZ
Functional Application
-
1
Frequency setting method: digital setting, analog setting, serial communication setting, multi-stage speed, PID setting, etc.
-
2
Simple PLC application, PID control function
-
3
Professional-level constant pressure water supply / constant temperature control application, automatic sleep and wake-up can be set arbitrarily
-
4
Multi-stage speed control function: 8-stage speed control, 16-stage speed control
-
5
4 sets of linear acceleration and deceleration time, which can be switched according to requirements, the highest resolution is 0.01s
-
6
Shortcut multi-function keys, user-definable multi-function shortcut keys
-
7
The software current limiting / overvoltage function can be set to keep the output current not exceeding the limit according to the load change and avoid frequent alarms
-
8
Automatic voltage adjustment function: when the grid voltage changes, it can automatically keep the output voltage constant
-
9
Provide dozens of various fault protection functions: short circuit, software current limit, fast current limit, software overcurrent, overtemperature, overvoltage, undervoltage, Input/ output phase loss protection function
-
10
Equipped with dual digital display keyboards as standard, two keyboards can be connected at the same time, and the keyboard type is automatically identified to support hot swapping
-
11
Independent trial time timing
Input and Output range
Input voltage range: single-phase 220V / three-phase 220V / three-phase 380V / three-phase 480V ±15%
Input frequency range: 47~63Hz
Output voltage range: 0~rated input voltage
Output frequency range: 0.00Hz~300.00Hz or 300.0Hz~3000.0Hz two frequency output
Peripheral Interface Features
-
1
Programmable digital input: 5 digital inputs (one of which supports high-speed pulse input)
-
2
Programmable high-speed input: up to 100KHz pulse input
-
3
Programmable analog input: 3 AI analog inputs; AI1 is the same as AI2: 0~10V or 0/4~20mA input, AI3: fixed as panel potentiometer
-
4
Analog output: 1 output, 0~20mA or 0~10V output can be selected respectively
-
5
Relay output: 1 independent output, contact load capacity 250VAC 3A
-
6
Programmable extension relay output: supports up to 100KHz pulse output, and supports parameter setting as collector open-drain switch output
-
7
Communication interface: 1 channel 485 modbus communication interface
-
8
Digital input supports two kinds of signal input: sink type (NPN) / source type (PNP)
-
9
External temperature detection: support 0~5V/0~10V/4~20mA temperature transmitter temperature display / temperature control
-
10
Expansion interface: 8-way breaker can be expanded, and functions can be customized according to requirements
Frequency Inverter Series
| Model No. | Input rated voltage (V) | Rated output power(KW) | Rated output current(A) | Dimension | Remark |
|---|---|---|---|---|---|
| SHBF400-02S0.75G | Single phase 220V ±15% | 0.75KW | 4A | 155.5X85X106 | A |
| SHBF700-02S1.5G | 1.5KW | 7A | 155.5X85X106 | ||
| SHBF700-02S2.2G | 2.2KW | 9.6A | 155.5X85X106 | ||
| SHBF700-02S3.7G | 3.7KW | 17A | 211X117.5X137 | B | |
| SHBF700-02S5.5G | 5.5KW | 25A | 259X148X167 | C | |
| SHBF700-02T0.75G | 3 phase 220V ±15% | 0.75KW | 3.8A | 155.5X85X106 | A |
| SHBF700-02T1.5G | 1.5KW | 5.1A | 155.5X85X106 | ||
| SHBF700-02T2.2G | 2.2KW | 9.6A | 155.5X85X106 | ||
| SHBF700-02T3.7G | 3.7KW | 17A | 211X117.5X137 | B | |
| SHBF700-02T5.5G | 5.5KW | 25A | 259X148X167 | C | |
| SHBF700-02T7.5G | 7.5KW | 32A | 259X148X167 | ||
| SHBF700-04T0.75G | 3 phase 380V ±15% | 0.75KW | 2.1A | 155.5X85X106 | A |
| SHBF700-04T1.5G | 1.5KW | 3.8A | 155.5X85X106 | ||
| SHBF700-04T2.2G | 2.2KW | 5.1A | 155.5X85X106 | ||
| SHBF700-04T3.0G | 3.0KW | 6.8A | 155.5X85X106 | ||
| SHBF700-04T4.0G | 4.0KW | 9A | 155.5X85X106 | ||
| SHBF700-04T5.5G | 5.5KW | 13A | 211X117.5X137 | B | |
| SHBF700-04T7.5G | 7.5KW | 17A | 211X117.5X137 | ||
| SHBF700-04T11G | 11KW | 25A | 259X148X167 | C | |
| SHBF700-04T15G | 15KW | 32A | 259X148X167 |
Structure Diagram
Frequently Asked Questions
Q: What control modes does this frequency inverter support?
The inverter supports multiple control modes including Linear V/F control, square V/f control, V/F separation mode, and SVPWM modulation to suit different application requirements.
Q: What is the difference in overload capacity between the G and P models?
The G model supports a 150% overload for 60 seconds and a 180% overload for 3 seconds. The P model supports a 120% overload for 60 seconds and a 150% overload for 3 seconds.
Q: What input voltage ranges are compatible with this series?
It supports single-phase 220V, three-phase 220V, three-phase 380V, and three-phase 480V with a fluctuation tolerance of ±15% at an input frequency range of 47~63Hz.
Q: How many speed control stages can be configured?
This frequency inverter features multi-stage speed control functions, supporting both 8-stage speed control and 16-stage speed control configurations.
Q: What built-in protection features does the inverter have?
It features comprehensive protection including short circuit protection (ensuring no explosion), input and output phase loss protection, software current limiting, fast current limiting, overtemperature, overvoltage, and undervoltage protection.