Introducing the SHR2DN Intelligent Motor Soft Starter, a cutting-edge solution developed for various industrial applications. Manufactured in China, this advanced product features a state-of-the-art digital processor capable of adjusting voltage and limiting electric current. The SHR2DN's unique intelligent electronic circuit provides optimal control and protective functionalities, allowing for linear acceleration with higher speeds while maintaining precise starting and stopping control for pumps, This versatile soft starter enables pre-set dual start-stop parameters, monitoring load conditions, and automatically adapting to energy-saving or light load modes. Its protective functions include electrical insulation testing, short circuit protection, phase loss detection, and an electronic RS485 communication interface that supports Modbus/Profibus protocols for comprehensive long-range monitoring and control, Ideal for industries such as textiles, metallurgy, petrochemicals, water treatment, shipping, pharmaceuticals, food processing, mining, and mechanical equipment, the SHR2DN is your go-to choice among reliable suppliers and factories in China. Experience efficiency and protection in motor control with the SHR2DN Intelligent Motor Soft Starter

    Product Profile

    SHR2DN is a new intelligent motor soft starter, SHR2DN with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump preset run at a low speed (rotating and overturning adjustment in short time of electro-controlling type). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing, and the protection of short circuit, phase loss and the electronic RS485 with communication interface use modbus/profibus protocol that generally realize the long-range control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry and mechanical equipment industry etc.

    Function

    • Multinational language supported, LCD display, set up the parameter in button type
    • RS485 with communication interface modbus/profibus protocol
    • Can programme set the signal relay
    • Super strong perfect control and protective function
    • Can be run online continuously without bypass. High reliability

    Parameters

    230-690V Motor Power
    Motor Power (KW) Size and Type of softstarter
    230V 400V 500V 690V Model Main voltage Control voltage Control inputs Functions Options
    4 7.5 11 15 SHR2DN17 -x -x -x -× + X…
    7.5 15 18.5 25 SHR2DN31 -x -x -x -× + ×…
    15 22 25 37 SHR2DN44 -x -x -x -x + x…
    18.5 30 37 55 SHR2DN58 -x -x -x -× + ×…
    22 37 45 59 SHR2DN72 -x -x -x -x + x…
    25 45 55 75 SHR2DN85 -x -x -x -× + ×…
    30 55 75 90 SHR2DN105 -x -x -x -× + ×…
    37 75 90 132 SHR2DN145 -x -x -x -x + x…
    45 90 110 160 SHR2DN170 -x -x -x -× + ×…
    55 110 132 200 SHR2DN210 -x -x -x -×+ ×…
    75 132 160 220 SHR2DN250 -x -x -x -X + X…
    90 160 200 257 SHR2DN310 -x -x -x -× + ×…
    110 200 250 355 SHR2DN390 -x -x -x -X + X…
    132 250 315 450 SHR2DN460 -x -x -x -× + ×…
    160 315 400 560 SHR2DN580 -x -x -x -×+×…
    200 400 500 710 SHR2DN720 -x -x -x -× + ×…
    250 450 560 800 SHR2DN820 -x -x -x -x + x…
    280 500 630 850 SHR2DN950 -x -x -x -X + X…
    Purchasing Guide

    For normal duty applications, we recommend the same rated power HPS2DN softstarters. As pump compressor or elevator, escalator conveyor belt(short).
    For heavy duty applications, we recommend one higher level HPS2DN soft starters. As centrifugal, fan, mill, mixer conveyor belt(long).

    Parameters

    General Information
    Supply voltage Line to line 230V-690V (to be specified) 10%
    Frequency 50/60Hz 4Hz(dual frequency)
    Control Supply 110-120V of 220-240V (to be specified)
    Control Inputs and Outputs 110-120V of 220-240V (to be specified)
    Load 3 phase, 3 wire, squirrel cage induction motor
    Operating temperature 0℃ to 50℃
    Storage temperature -20 ℃ to 70℃
    Maximum starting time 30 seconds
    Maximum starts per hour 4 starts per hour at 400% In, Up to 60 starts per hour at lower load applications
    Operating Parameters
    Starter FLC Starter Full Load Current 17~950 Amp
    Motor FLA Motor Full Load Ampere 50%-100% of starter FLC
    Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop
    Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads
    Initial voltage 10%-50% Un*(can be extended to 80% Un)
    Current limit 100%-400% of Motor FLA* (can be extended to 500%)
    Ramp-up time 1-30 seconds (can be extended to 90s*)
    Ramp-down time 1-30 seconds(can be extended to 90s*)
    Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA.
    Energy saving Activated when motor is lightly loaded for extended periods of time
    Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds
    Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho feedback linearity
    Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8, for dual adjustment)
    Motor Protection
    Too many starts Determines maximum number of starts allowable during Start Period. Range 1-10 starts in start period 1-60 minutes
    Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated
    Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds*
    Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running
    Electronic overload (I²t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in, 1-10 seconds
    Under current Starter trips when current drops below 20%-90% In, time delay 1-40 seconds
    Under voltage(**) Starter trips when mains voltage drops below 120–600V, time delay 1–10 seconds
    Over voltage Starter trips when mains voltage increases above 150-750V, time delay 1-10 seconds
    Phase loss (under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency
    Phase sequence Starter trips when phase sequence is incorrect
    Long slow speed time Starter trips if operating at slow speed longer than 30 seconds
    Wrong connection Prevents starting if the motor is incorrectly connected to the starter
    Shorted SCR Prevents starting when one or more SCRs are shorted
    Heatsink over temperature Starter trips when heatsink temperature rises above 85℃
    External fault Starter trips when an external contact closes for 2 seconds
    Motor insulation (optional) Alarm level setting 0.2-5M. Trips when motor insulation decreases below 0.2-5M setting. The thyristors must be protected against short circuit
    Thyristor Protection Metal Oxide Varistors (MOVs) and snubber circuits
    Control
    Analogue I/O Input of motor overheat signal. Output of analog signals of motor current
    Displays LCD in 4 selectable languages and 8 LEDs
    Keypad 6 clearly defined keys for easy setting
    Aux. contact-immediate 1 C/O, 8A, 250V A.C, 2000VA (delay 0-60 seconds)
    Aux. contact-end of acceleration 1 C/O, 8A, 250V A.C, 2000VA (delay 0-120 seconds)
    Fault contact 1 C/O, 8A, 250V A.C, 2000VA (selectable as trip or trip fail safe)
    Insulation alarm contact (optional) 1 C/O, 8A, 250V A.C, 2000VA
    Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

    Measurement

    Frequently Asked Questions

    What are the primary applications for the SHR2DN soft starter?
    The SHR2DN intelligent soft starter is widely used in the textile industry, metallurgy industry, petrochemical industry, water treatment, shipping, medicine, food processing, mining, and general mechanical equipment industries.
    Does the SHR2DN soft starter support remote monitoring?
    Yes, it features an optional RS485 communication interface supporting Modbus/Profibus protocols, which enables long-range control, supervision, and monitoring.
    What is the difference between normal duty and heavy duty selection?
    For normal duty (pumps, short conveyor belts, escalators), you can select the same rated power soft starter. For heavy duty applications (centrifugal fans, mills, mixers, long conveyor belts), it is recommended to select a soft starter that is one level higher.
    What protective functions does the SHR2DN offer?
    It provides comprehensive motor protection including short circuit protection, phase loss, under/over voltage, under current, electronic overload (I²t), phase sequence, wrong connection, shorted SCR, and heatsink over-temperature protection.
    Can this soft starter run continuously without a bypass?
    Yes, the SHR2DN soft starter is designed to run online continuously without a bypass, offering high reliability for demanding industrial applications.
    What is the operating temperature range for the device?
    The operating temperature range is from 0℃ to 50℃, and the storage temperature range is from -20℃ to 70℃.