Leave Your Message
SHR3E Mini Intelligent Soft Starter from China Suppliers - Reliable Factory Solutions for Motor Control and Protection
Hot Products

SHR3E Mini Intelligent Soft Starter from China Suppliers - Reliable Factory Solutions for Motor Control and Protection

The SHR3E series soft starter is a cutting-edge product developed by SHUOSHI Electric, tailored to meet the specific needs of customers through years of industry experience. As a leading manufacturer and factory in China, we understand the importance of integrating advanced motor control and protection features. Our innovative design enhances application reliability and user convenience, making it an ideal choice for various industrial applications. Trust SHUOSHI Electric as your preferred supplier for high-quality soft starters that elevate your operational efficiency

    Product Profile

    The SHR3E soft starter is a brand-new integrated intelligent motor control and protection product launched by Shuoshi Electric. Combining rich experience in industry applications and a deep understanding of customers' special application requirements, and based on years of product research and development, it has added new functions, improving the reliability and convenience of customer applications.

    The soft starter is a digital motor soft starting product. It can control the motor to accelerate smoothly during the starting process and decelerate smoothly during the stopping process, and it provides protection functions for both the motor and the product itself. It is the best upgraded alternative to traditional star-delta and reactor starters. It is suitable for asynchronous squirrel-cage motors with a power range of 0.75-90kW.

    The soft starter is equipped with an RS485 communication interface and supports the Modbus protocol, enabling comprehensive remote control and monitoring by a microcomputer. It can be widely used in industries such as textiles, metallurgy, agriculture, petroleum, chemical, water treatment, shipping, transportation, pharmaceuticals, food processing, mining, and mechanical equipment.

    Function

    The SHR3E series soft starters can directly set the parameters of starting time, stopping time and initial voltage through three potentiometers. All models in the SHR3E series soft starters have built-in bypass relays. Users do not need to additionally install external bypass contactors. The soft start adopts the voltage ramp starting method.

    During the soft stop process, the output torque can be maintained (final torque control), thus effectively preventing the water hammer effect. It can adopt two connection methods: delta external connection and star external connection. Real-time data (phase A current, phase B current, phase C current, average current, etc.) can be read through communication. *Note

    Fault history records (10 fault history records, etc.) can be read through communication. *Note

    Statistical data (cumulative number of starts, cumulative running time, cumulative number of trips, etc.) can be read through communication. *Note

    Protection functions of the SHR3E series soft starters:

    1) Over-current protection

    2) Over-current delay protection

    3) Over-load protection (Over-load class: CLASS10A, CLASS10, CLASS20, CLASS30)

    4) Three-phase current imbalance protection

    5) Phase loss/under-voltage protection

    6) Phase sequence protection

    7) SCR (Silicon-Controlled Rectifier) over-temperature protection

    There is one start/stop control input point.
    RS-485 communication bus interface. *Note
    It is optional to have a built-in start/stop control switch. *Note
    There are two relay outputs (running relay and fault relay).

    *Note 1: It is an optional accessory. This function can only be used when the RS-485 communication bus interface (Modbus RTU protocol) is selected.

    *Note 2: It is an optional accessory. This function can only be used when the built-in start/stop control switch is selected.

    Features

    • Three-phase control;
    • Operating voltage: 200/400/500VAC;
    • Wide range of control voltage: 100~240VAC 50/60Hz or 24VDC;
    • SLR rated operating current: 1.5~150A;
    • The control board is added with a protective coating;
    • Direct parameter setting via potentiometers makes the setting and operation simpler and more convenient. All series have built-in bypass, which reduces energy consumption and is easy to install;
    • Modbus RTU is optional for monitoring;
    • Supports all mainstream communication protocols;
    • Built-in motor protection function;
    • Integrated structure design with a protection level of IP21: It can effectively resist dust, moisture and corrosive gases, significantly extending the service life.

    Feature Description

    Feature Specification
    Input Voltage 220/400/500VAC 50/60Hz
    Control Source Voltage 100~240VAC or 24VDC 50/60Hz
    Current class 1.5……150A
    Initial Voltage 30%~70%
    Start Slope 1~30Sec
    Stop Slope 0~30Sec
    Overload 3 x le for 7 Sec (Valid for 50 % on time and 50 % off time)
    Times of start per hour <5, 5-10 (light load or no-load)
    Overload grade 10A
    Operation Environmental temperature 0℃ to +50℃ (32℉ to 122℉)
    Store temperature -40℃ to +70℃ (-40℉ to 158℉)
    Maximum altitude 1000m (3280ft)
    Ingress Protection grade IP21
    SHR3E Soft Starter Model Selection Guide

    Note:

    1. Rated voltage of the main power supply: 22: 220V; 40: 400V; 50: 500V;

    2. Rated current: 1.5~150A;

    3. Control power supply voltage: A: 100~240VAC; B: 24VDC;

    4. Control mode of the soft starter: 3P3: Three-phase three-control; 1P1: Single-phase single-control.

    Internal Control Form & Connection

    Below are the details regarding the internal control form and external connection options for the SHR3E soft starter.

    Internal control form

    Internal control form of the soft starter

    Application internal & External connection

    Application internal and External connection

    Product Selection

    Three-phase Three-control (3P3 Model Selection):

    Model Motor power rating (Pe/kW) SLR Rated current (le/A) Structure (F) Weight (kg)
    220V 400V 500V
    SHR3EXX1T5-X-3P3 0.37 0.75 1.1 1.5 A 1
    SHR3EXX2T2-X-3P3 0.55 1.1 1.5 2.2 A 1
    SHR3EXX03-X-3P3 0.75 1.5 2.2 3 A 1
    SHR3EXX4T5-X-3P3 1.1 2.2 3.7 4.5 A 1
    SHR3EXX7T5-X-3P3 1.5 3.7 5.5 7.5 A 1
    SHR3EXX11-X-3P3 2.2 5.5 7.5 11 A 1
    SHR3EXX 15-X-3P3 3.7 7.5 11 15 B 1.4
    SHR3EXX22-X-3P3 5.5 11 15 22 B 1.4
    SHR3EXX30-X-3P3 7.5 15 18.5 30 C 2.4
    SHR3EXX37-X-3P3 11 18.5 22 37 C 2.4
    SHR3EXX45-X-3P3 15 22 30 45 C 2.4
    SHR3EXX60-X-3P3 18.5 30 37 60 C 2.4
    SHR3EXX75-X-3P3 22 37 45 75 C 2.4
    SHR3EXX90-X-3P3 25 45 55 90 D 5
    SHR3EXX110-X-3P3 30 55 75 110 D 5.2
    SHR3EXX150-X-3P3 37 75 90 150 D 5.2

    Note:

    1. 1T5 means 1.5A, 4T5 means 4.5A, 7T5 means 7.5A in Rated current.

    2. Other voltage classes can be made to order.

    Single-phase Single-control (1P1 Model Selection):

    Model Motor power rating (Pe/kW) SLR Rated current (le/A) Structure (F) Weight (kg)
    220V 400V
    SHR3EXX02-X-1P1 0.37 0.55 2 A 1
    SHR3EXX03-X-1P1 0.55 0.75 3 A 1
    SHR3EXX04-X-1P1 0.75 1.1 4 A 1
    SHR3EXX06-X-1P1 1.1 1.5 6 A 1
    SHR3EXX09-X-1P1 1.5 2.2 9 A 1
    SHR3EXX12-X-1P1 2.2 3.7 12 A 1
    SHR3EXX20-X-1P1 3.7 5.5 20 C 2.4
    SHR3EXX30-X-1P1 5.5 7.5 30 C 2.4
    SHR3EXX37-X-1P1 7.5 11 45 C 2.4

    In applications with conventional loads:

    Such as water pumps, compressors, ventilation equipment, conveying equipment, etc. The SHR3E soft starter can be selected according to the rated power of the electric motor. (Note: For heating equipment, the selection can be made according to the rated current.)

    For applications with heavy loads:

    Such as centrifugal fans, mixers, grinders, blenders, or equipment that needs to be frequently started within a short period of time, SOSICN recommends that you select a soft starter one rating higher than the rated power of the electric motor.

    Application Diagram

    SHR3E Soft Starter Application Diagram

    Parameters

    General Parameters
    Frequency 50/60Hz±5Hz
    Rated Main Voltage 220-500±10% VAC (chosen by customer); 400VAC±10% (acquiescent)
    Control Source Voltage 100-240VAC-15%+10% or 24VDC (chosen by customer); 100-240VAC±10% (acquiescent)
    The motor adapted Three-phase squirrel-cage induction motor
    Times of start per hour <5 at 400% FLA
    Operating data
    Motor rated operational current Motor full load current: 1.5-150A
    Initial voltage 30%~70% Un
    Start Slope 1-30 seconds
    Stop Slope 0-30 seconds
    Motor protections
    Over current During start, operation, stop, output current over limit
    Unbalanced Current Output current unbalanced level beyond the setting
    I²t overload May set to 10A, 10… overload protection base on the setting to delay protection stop
    Missing phase/ No voltage Stop the softstarter when 1 or 2 phases failed Or no voltage input
    Thyristor(SCR) overtemp Stop the softstarter when the radiator temperature rises above 80℃
    Phase sequence Forbid starting when the input phase sequence is wrong (If the function is unnecessary, please tell us before ordering)
    Under current Stop the softstarter when the current lower than under current protection value
    Max start time Stop the softstarter when the time of starting process exceeds the max start time

    Rapid fuse

    Model SCR I²T (A²S) Fuse rating
    SHR3EXX1T5-X-3P3 70 5A
    SHR3EXX2T2-X-3P3 150 10A
    SHR3EXX03-X-3P3 270 10A
    SHR3EXX4T5-X-3P3 610 16A
    SHR3EXX7T5-X-3P3 1700 25A
    SHR3EXX 11-X-3P3 3630 32A
    SHR3EXX 15-X-3P3 5000 40A
    SHR3EXX22-X-3P3 7500 50A
    SHR3EXX30-X-3P3 10000 63A
    SHR3EXX37-X-3P3 11000 100A
    SHR3EXX45-X-3P3 12000 160A
    SHR3EXX60-X-3P3 15000 200A
    SHR3EXX75-X-3P3 18000 250A
    SHR3EXX90-X-3P3 40000 315A
    SHR3EXX110-X-3P3 60000 315A
    SHR3EXX150-X-3P3 100000 400A

    Product Structure & Schematic Diagram

    Product Structure Size

    SHR3E Product Structure Size

    Schematic Diagram

    SHR3E Schematic Diagram

    Frequently Asked Questions (FAQ)

    What is the power range and motor type suitable for the SHR3E soft starter?

    The SHR3E soft starter is designed for three-phase asynchronous squirrel-cage induction motors with a power range of 0.75-90kW.

    Does the SHR3E soft starter require an external bypass contactor?

    No, all models in the SHR3E series feature built-in bypass relays, eliminating the need for users to install external bypass contactors, which saves installation space and reduces energy consumption.

    What control and communication capabilities does it offer?

    It features direct parameter settings via three potentiometers (starting time, stopping time, and initial voltage). For communication, it includes an optional RS-485 interface supporting Modbus RTU protocol for remote control and real-time monitoring.

    What integrated protection features are built into this soft starter?

    It offers comprehensive protection functions, including over-current, over-current delay, overload (CLASS10A, CLASS10, CLASS20, CLASS30), three-phase current imbalance, phase loss/under-voltage, phase sequence, and SCR over-temperature protection.

    How should I choose the right model for heavy-load applications?

    For conventional loads like water pumps and compressors, selection can be based on the rated power of the motor. For heavy loads like centrifugal fans, mixers, or grinders, it is recommended to select a soft starter that is one rating higher than the rated motor power.

    What is the environmental protection level of the SHR3E soft starter?

    The SHR3E soft starter features an integrated structure design with an IP21 protection grade, allowing it to effectively resist dust, moisture, and corrosive gases for a prolonged service life.